Comput Biol Med ; 168: 107714, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38035862

RESUMEN

BACKGROUND: Balloon burst during transcatheter aortic valve replacement (TAVR) is serious complication. This study pioneers a novel approach by combining image observation and computer simulation validation to unravel the mechanism of balloon burst in a patient with bicuspid aortic valve (BAV) stenosis. METHOD: A new computational model for balloon pre-dilatation was developed by incorporating the element failure criteria according to the Law of Laplace. The effects of calcification and aortic tissue material parameters, friction coefficients, balloon types and aortic anatomy classification were performed to validate and compare the expansion behavior and rupture mode of actual balloon. RESULTS: Balloon burst was dissected into three distinct stages based on observable morphological changes. The mechanism leading to the complete transverse burst of the non-compliant balloon initiated at the folding edges, where contacted with heavily calcified masses at the right coronary sinus, resulting in high maximum principal stress. Local sharp spiked calcifications facilitated rapid crack propagation. The elastic moduli of calcification significantly influenced balloon expansion behavior and crack morphology. The simulation case of the calcific elastic modulus was set at 12.6 MPa could closely mirror clinical appearance of expansion behavior and crack pattern. Furthermore, the case of semi-compliant balloons introduced an alternative rupture mechanism as pinhole rupture, driven by local sharp spiked calcifications. CONCLUSIONS: The computational model of virtual balloons could effectively simulate balloon dilation behavior and burst mode during TAVR pre-dilation. Further research with a larger cohort is needed to investigate the balloon morphology during pre-dilation by using this method to guide prosthesis sizing for potential favorable outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Dilatación , Simulación por Computador , Análisis de Elementos Finitos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Diseño de Prótesis
2.
BMC Cardiovasc Disord ; 22(1): 493, 2022 11 20.
Artículo en Inglés | MEDLINE | ID: mdl-36404303

RESUMEN

BACKGROUND: Drug-coated balloon (DCB) is a novel and effective device for coronary artery disease patients with in-stent restenosis (ISR). However, the incidence and possible influencing factors associated with binary restenosis have not yet been adequately assessed. METHODS: The data are extracted from a prospective, multicenter, randomized controlled trial. A total of 211 patients with ISR were enrolled at 13 centers from August 2017 to October 2018 and treated with DCB. At the 9-month coronary angiographic follow-up, patients were divided into restenosis and non-restenosis groups, and demographic data, lesion features, and laboratory tests were retrospectively reviewed. Furthermore, logistic regression analysis was used to identify possible influencing factors. RESULTS: All patients successfully underwent treatment, and 166 patients with 190 lesions took part in angiography follow-ups at 9 months. Of these, 41 patients with 44 target lesions developed restenosis following treatment, and the incidence of ISR was 24.7%. There were significant differences in the average length of target lesions and the number of multivessel lesions and fasting plasma glucose (FBG) between the two groups (p < 0.05). Demographic data, cardiac risk factors, left ventricular ejection fractions (LVEF), blood routine tests, biochemical tests, and other features of devices and lesions showed no difference. Logistic regression analyses showed that FBG > 6.1 mmol/L (OR: 7.185 95% CI: 2.939-17.567 P < 0.001) and length of lesion (OR:1.046 95% CI: 1.001-1.093 P = 0.046) were associated risk factors. CONCLUSIONS: The longer length of lesions, more target lesions and FBG > 6.1 mmol/L per individual may be characteristics of patients showing ISR following treatment. Studies with larger sample size, and more complete follow-up data are needed in the future to expend on these findings. TRIAL REGISTRATION: No.: NCT04213378, first posted date (30/12/2019).


Asunto(s)
Angioplastia de Balón , Reestenosis Coronaria , Humanos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología , Incidencia , Estudios Retrospectivos , Estudios Prospectivos , Angioplastia de Balón/efectos adversos , Constricción Patológica/complicaciones